4,690 research outputs found
Gray scale and color Doppler sonography in the diagnosis of carpal tunnel syndrome
AbstractPurposeTo determine the diagnostic accuracy of gray scale and color Doppler sonography in the diagnosis of patients with carpal tunnel syndrome.Patients and methodsA total of 53 wrists in 41 consecutive patients with clinical suspicion of carpal tunnel syndrome, referred from the Department of Physical medicine, Rheumatology & Rehabilitation were examined with ultrasonography using a 12MHz linear array transducer. The presence of median nerve edema, swelling, and bowing of the flexor retinaculum was evaluated by gray scale sonography, while intraneural hypervascularity was evaluated by color Doppler sonography. Sensitivity and specificity were calculated for each sonographic feature and compared with electrodiagnostic test (EDT) results.ResultsElectrodiagnostic tests confirmed carpal tunnel syndrome in 48 wrists. A median nerve cross sectional area (CSA) of 11mm2 was calculated as a definition of median nerve swelling. In comparison with electrodiagnostic tests, median nerve swelling showed the highest accuracy (89%) among the gray scale sonographic criteria, and the presence of median nerve hypervascularization showed the highest accuracy (94%) among all sonographic criteria. Median nerve edema and bowing of the flexor retinaculum showed accuracies of 81% and 77% respectively.ConclusionMedian nerve intraneural hypervascularity detected by color Doppler sonography is more accurate in detection of median nerve involvement than gray scale sonography criteria in patients with suspected carpal tunnel syndrome
CYP1B1 and myocilin gene mutations in Egyptian patients with primary congenital glaucoma
Purpose: Primary congenital glaucoma (PCG) accounts for 26–29% of childhood blindness in Egypt. The identification of disease causing mutations has not been extensively investigated. We aimed to examine the frequency of CYP1B1 and MYOC mutations in PCG Egyptian patients, and study a possible genotype/phenotype correlation.Methods: Ninety-eight patients with PCG diagnosed at the Ophthalmology department ofAlexandria Main University Hospital were enrolled. Demographic and phenotypic characteristics were recorded. Patients and 100 healthy subjects (control group) were screened for two mutations in CYP1B1 gene (G61E, R368H) and one mutation in MYOC gene (Gln48His) using polymerase chain reaction/restriction fragment length polymorphism (PCR/RFLP). Phenotypic characteristics pertaining to disease severity were compared.Results: Nineteen patients (19%) with PCG were found positive for one or more of the mutations screened for. Seven patients (7%) were homozygous for the G61E mutation. Ten patients (10%) were heterozygous; 6 for the G61E mutation, 2 for the R368H mutation and 2 for the Gln48His mutation. Two patients (2%) were double heterozygotes harboring a R368H as well as a Gln48His mutation. The most common mutation observed was the G61E in 13 patients; 7 homozygotes and 6 heterozygotes for the mutation. The control group were negative for all mutations screened for. No significant correlations between the mutations and phenotype severity were detected. A statistically significant positive correlation however was found between the different mutations andeach of the IOP and the cup/disk ratio.Conclusion: The current study further endorses the role of CYP1B1 mutations in the etiology of PCG among Egyptian patients and is the first study to report MYOC gene mutation in Egyptian patients with PCG
A search for resonant production of pairs in $4.8\ \rm{fb}^{-1}p\bar{p}\sqrt{s}=1.96\ \rm{TeV}$
We search for resonant production of tt pairs in 4.8 fb^{-1} integrated
luminosity of ppbar collision data at sqrt{s}=1.96 TeV in the lepton+jets decay
channel, where one top quark decays leptonically and the other hadronically. A
matrix element reconstruction technique is used; for each event a probability
density function (pdf) of the ttbar candidate invariant mass is sampled. These
pdfs are used to construct a likelihood function, whereby the cross section for
resonant ttbar production is estimated, given a hypothetical resonance mass and
width. The data indicate no evidence of resonant production of ttbar pairs. A
benchmark model of leptophobic Z \rightarrow ttbar is excluded with m_{Z'} <
900 GeV at 95% confidence level.Comment: accepted for publication in Physical Review D Sep 21, 201
Evidence for the exclusive decay Bc+- to J/psi pi+- and measurement of the mass of the Bc meson
We report first evidence for a fully reconstructed decay mode of the
B_c^{\pm} meson in the channel B_c^{\pm} \to J/psi \pi^{\pm}, with J/psi \to
mu^+mu^-. The analysis is based on an integrated luminosity of 360 pb$^{-1} in
p\bar{p} collisions at 1.96 TeV center of mass energy collected by the Collider
Detector at Fermilab. We observe 14.6 \pm 4.6 signal events with a background
of 7.1 \pm 0.9 events, and a fit to the J/psi pi^{\pm} mass spectrum yields a
B_c^{\pm} mass of 6285.7 \pm 5.3(stat) \pm 1.2(syst) MeV/c^2. The probability
of a peak of this magnitude occurring by random fluctuation in the search
region is estimated as 0.012%.Comment: 7 pages, 3 figures. Version 3, accepted by PR
Evidence for t\bar{t}\gamma Production and Measurement of \sigma_t\bar{t}\gamma / \sigma_t\bar{t}
Using data corresponding to 6.0/fb of ppbar collisions at sqrt(s) = 1.96 TeV
collected by the CDF II detector, we present a cross section measurement of
top-quark pair production with an additional radiated photon. The events are
selected by looking for a lepton, a photon, significant transverse momentum
imbalance, large total transverse energy, and three or more jets, with at least
one identified as containing a b quark. The ttbar+photon sample requires the
photon to have 10 GeV or more of transverse energy, and to be in the central
region. Using an event selection optimized for the ttbar+photon candidate
sample we measure the production cross section of, and the ratio of cross
sections of the two samples. Control samples in the dilepton+photon and
lepton+photon+\met, channels are constructed to aid in decay product
identification and background measurements. We observe 30 ttbar+photon
candidate events compared to the standard model expectation of 26.9 +/- 3.4
events. We measure the ttbar+photon cross section to be 0.18+0.08 pb, and the
ratio of the cross section of ttbar+photon to ttbar to be 0.024 +/- 0.009.
Assuming no ttbar+photon production, we observe a probability of 0.0015 of the
background events alone producing 30 events or more, corresponding to 3.0
standard deviations.Comment: 9 pages, 3 figure
Precision Top-Quark Mass Measurements at CDF
We present a precision measurement of the top-quark mass using the full
sample of Tevatron TeV proton-antiproton collisions collected
by the CDF II detector, corresponding to an integrated luminosity of 8.7
. Using a sample of candidate events decaying into the
lepton+jets channel, we obtain distributions of the top-quark masses and the
invariant mass of two jets from the boson decays from data. We then compare
these distributions to templates derived from signal and background samples to
extract the top-quark mass and the energy scale of the calorimeter jets with
{\it in situ} calibration. The likelihood fit of the templates from signal and
background events to the data yields the single most-precise measurement of the
top-quark mass, \mtop = 172.85 \pm\pmComment: submitted to Phys. Rev. Let
Top quark mass measurement using the template method at CDF
We present a measurement of the top quark mass in the lepton+jets and
dilepton channels of decays using the template method. The data
sample corresponds to an integrated luminosity of 5.6 fb of
collisions at Tevatron with TeV, collected with the CDF II
detector. The measurement is performed by constructing templates of three
kinematic variables in the lepton+jets and two kinematic variables in the
dilepton channel. The variables are two reconstructed top quark masses from
different jets-to-quarks combinations and the invariant mass of two jets from
the decay in the lepton+jets channel, and a reconstructed top quark mass
and , a variable related to the transverse mass in events with two
missing particles, in the dilepton channel. The simultaneous fit of the
templates from signal and background events in the lepton+jets and dilepton
channels to the data yields a measured top quark mass of Comment: submitted to Phys. Rev.
Combined search for the standard model Higgs boson decaying to a bb pair using the full CDF data set
We combine the results of searches for the standard model Higgs boson based
on the full CDF Run II data set obtained from sqrt(s) = 1.96 TeV p-pbar
collisions at the Fermilab Tevatron corresponding to an integrated luminosity
of 9.45/fb. The searches are conducted for Higgs bosons that are produced in
association with a W or Z boson, have masses in the range 90-150 GeV/c^2, and
decay into bb pairs. An excess of data is present that is inconsistent with the
background prediction at the level of 2.5 standard deviations (the most
significant local excess is 2.7 standard deviations).Comment: To be published in Phys. Rev. Lett (v2 contains minor updates based
on comments from PRL
Measurement of the Lifetime Difference Between B_s Mass Eigenstates
We present measurements of the lifetimes and polarization amplitudes for B_s
--> J/psi phi and B_d --> J/psi K*0 decays. Lifetimes of the heavy (H) and
light (L) mass eigenstates in the B_s system are separately measured for the
first time by determining the relative contributions of amplitudes with
definite CP as a function of the decay time. Using 203 +/- 15 B_s decays, we
obtain tau_L = (1.05 +{0.16}/-{0.13} +/- 0.02) ps and tau_H = (2.07
+{0.58}/-{0.46} +/- 0.03) ps. Expressed in terms of the difference DeltaGamma_s
and average Gamma_s, of the decay rates of the two eigenstates, the results are
DeltaGamma_s/Gamma_s = (65 +{25}/-{33} +/- 1)%, and DeltaGamma_s = (0.47
+{0.19}/-{0.24} +/- 0.01) inverse ps.Comment: 8 pages, 3 figures, 2 tables; as published in Physical Review Letters
on 16 March 2005; revisions are for length and typesetting only, no changes
in results or conclusion
- …